Vutova K.Vassileva V.Stefanova V.Amalnerkar D.Tanaka T.2024-07-102024-07-102024-07-102024-07-102019-06-012075-470110.3390/met9060683SCOPUS_ID:85070677460https://rlib.uctm.edu/handle/123456789/540This study reveals the efficiency of the electron beam processing of titanium technogenic material with a high level of impurities and the quality of the obtained metal in correlation to process parameters which are discussed. The influence of the beam power and melting time on the composition variation, morphologies, hardness of metal samples and mass losses is investigated. Based on the different technological parameters, the removal efficiency of impurities is also discussed, and the corresponding experiments are carried out in order to make a comparison. Different thermal process conditions are realized during the single-melt operation. Chemical and metallographic analyses are performed, and the results are discussed. The hardness of the titanium decreases by prolonging the time of the electron beam processing. A maximal overall removal efficiency of 99.975% is seen at 5.5 kW beam power for a 40 min melting time and the best purification of Ti (99.996%) is achieved.enEffect of electron beam method on processing of titanium technogenic materialArticle