BENEFITS FROM THE USE OF WIRE-COIL INSERTS IN WATER TRANSITIONAL AND LOW TURBULENT FLOW The Influence of the Wire-Coil Pitch
creativework.keywords | benefits, heat transfer enhancement, pitch of wire-coil insert, transitional and low turbulent flow | |
creativework.publisher | Serbian Society of Heat Transfer Engineers | en |
dc.contributor.author | Zimparov V. | |
dc.contributor.author | Bonev P. | |
dc.contributor.author | Angelov M. | |
dc.contributor.author | Hristov J. | |
dc.date.accessioned | 2024-07-10T14:27:05Z | |
dc.date.accessioned | 2024-07-10T14:50:11Z | |
dc.date.available | 2024-07-10T14:27:05Z | |
dc.date.available | 2024-07-10T14:50:11Z | |
dc.date.issued | 2022-01-01 | |
dc.description.abstract | Five wire-coil inserts with fixed wire diameter and different pitches, fitted inside a round tube have been experimentally studied in a transitional and low turbulent flow. Water was used as a working fluid at a wide range of flow conditions: 103 < Re < 104 and 3.9 < Pr < 10.0. The geometrical parameters of the inserts are: e/Di = 0.070, and p/e = 6.7, 9.0, 10.0, 12.5, and 15.0. The variation of the friction factor and heat transfer coefficients have been obtained and compared with those of the smooth pipe. Performance evaluation criteria for the cases FG-1a, FG-2a, and VG-2a have been used to evaluate the maximum and real benefit that can be obtained. The greatest benefit can be achieved with the pitch of the wire-coil insert p/e = 10.0. | |
dc.identifier.doi | 10.2298/TSCI211206060Z | |
dc.identifier.issn | 0354-9836 | |
dc.identifier.scopus | SCOPUS_ID:85135534789 | en |
dc.identifier.uri | https://rlib.uctm.edu/handle/123456789/734 | |
dc.language.iso | en | |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85135534789&origin=inward | |
dc.title | BENEFITS FROM THE USE OF WIRE-COIL INSERTS IN WATER TRANSITIONAL AND LOW TURBULENT FLOW The Influence of the Wire-Coil Pitch | |
dc.type | Article | |
oaire.citation.issue | 4 | |
oaire.citation.volume | 26 |