Dead time influence on operating modes of transistor resonant inverter with pulse frequency modulation (PFM)
| creativework.keywords | Dead time, Pulse frequency modulation, Resonant inverter | |
| creativework.publisher | Institute of Advanced Engineering and Science | en |
| dc.contributor.author | Antchev H.M. | |
| dc.contributor.author | Antchev M.H. | |
| dc.date.accessioned | 2024-07-10T14:27:04Z | |
| dc.date.accessioned | 2024-07-10T14:49:29Z | |
| dc.date.available | 2024-07-10T14:27:04Z | |
| dc.date.available | 2024-07-10T14:49:29Z | |
| dc.date.issued | 2019-12-01 | |
| dc.description.abstract | This study explores the impact of dead-time on the transistor resonant inverter operating modes depending on the ratio of the transistor switching frequency and the resonant frequency of the series-resonance circuit in the diagonal of the transistor bridge. On the basis of theoretical data and experimental results, a dead-time limitation relation has been offered-besides for a minimum value but for a maximum value. This provides extension of the operating mode range in zero voltage switching (ZVS). | |
| dc.identifier.doi | 10.11591/ijpeds.v10.i4.pp1815-1822 | |
| dc.identifier.issn | 2088-8694 | |
| dc.identifier.scopus | SCOPUS_ID:85071301387 | en |
| dc.identifier.uri | https://rlib.uctm.edu/handle/123456789/542 | |
| dc.language.iso | en | |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85071301387&origin=inward | |
| dc.title | Dead time influence on operating modes of transistor resonant inverter with pulse frequency modulation (PFM) | |
| dc.type | Article | |
| oaire.citation.issue | 4 | |
| oaire.citation.volume | 10 |