Using bremsstrahlung X-Ray for positioning of the filler wire during electron beam surfacing

creativework.publisherInstitute of Physics Publishinghelen.craven@iop.orgen
dc.contributor.authorVarushkin S.
dc.contributor.authorTrushnikov D.
dc.contributor.authorKoleva E.
dc.contributor.authorShamov D.
dc.date.accessioned2024-07-10T14:27:04Z
dc.date.accessioned2024-07-10T14:49:02Z
dc.date.available2024-07-10T14:27:04Z
dc.date.available2024-07-10T14:49:02Z
dc.date.issued2018-10-19
dc.description.abstractThis work aims to assess the bremsstrahlung X-Ray signal from the processing zone obtained by the use of a solid wire during electron beam surfacing. Applications of the bremsstrahlung X-Ray signal in the control systems allow positioning of the filler wire. During the experiments, a scintillation detector based on monocrystalline iodine cesium and silicone photomultiplier was used for registration of the X-Ray signal. Circle oscillations of the electron beam create the informative component. Synchronous storage method was applied for mathematical treatment of the recorded signal.
dc.identifier.doi10.1088/1742-6596/1089/1/012009
dc.identifier.issn1742-6596
dc.identifier.issn1742-6588
dc.identifier.scopusSCOPUS_ID:85056314195en
dc.identifier.urihttps://rlib.uctm.edu/handle/123456789/500
dc.language.isoen
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056314195&origin=inward
dc.titleUsing bremsstrahlung X-Ray for positioning of the filler wire during electron beam surfacing
dc.typeConference Paper
oaire.citation.issue1
oaire.citation.volume1089
Files