COMMERCIAL AND LABORATORY EXPERIENCE WITH CATALYTIC CRACKING OF STRAIGHT RUN HYDROTREATED VACUUM GAS OIL AND H-OIL GAS OILS

No Thumbnail Available
Date
2022-01-01
External link to pdf file
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85125262732&origin=inward
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This study presents for the first time an investigation of fluid catalytic cracking of 100 % H-vacuum gas oil at a commercial FCC unit. 100 % straight run hydrotreated vacuum gas oil (HTSRVGO) and 100 % H-vacuum gas oil have been cracked in the commercial LUKOIL Neftohim Burgas fluid catalytic cracking and in a laboratory confined ebbulated bed ACE catalytic cracking unit. The relations between the operating conditions of the commercial FCC unit and conversion level in both cases 100 % HTSRVGO and its blends with H-Oil VGO were investigated using intercriteria analysis. Multiple regressions were developed to quantify the effect of the operating conditions as well as quantity and quality of H-Oil VGO on conversion level in the commercial FCC unit. ACE laboratory tests with feed containing about 20 % H-Oil VGO at different catalyst-to-oil ratios and reaction temperature were performed and the results are discussed.
Description
Keywords
Citation
Collections